But you dont really care 'bout voltage, do ya?
Lemmy Shitpost
Welcome to Lemmy Shitpost. Here you can shitpost to your hearts content.
Anything and everything goes. Memes, Jokes, Vents and Banter. Though we still have to comply with lemmy.world instance rules. So behave!
Rules:
1. Be Respectful
Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.
Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.
...
2. No Illegal Content
Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.
That means:
-No promoting violence/threats against any individuals
-No CSA content or Revenge Porn
-No sharing private/personal information (Doxxing)
...
3. No Spam
Posting the same post, no matter the intent is against the rules.
-If you have posted content, please refrain from re-posting said content within this community.
-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.
-No posting Scams/Advertisements/Phishing Links/IP Grabbers
-No Bots, Bots will be banned from the community.
...
4. No Porn/Explicit
Content
-Do not post explicit content. Lemmy.World is not the instance for NSFW content.
-Do not post Gore or Shock Content.
...
5. No Enciting Harassment,
Brigading, Doxxing or Witch Hunts
-Do not Brigade other Communities
-No calls to action against other communities/users within Lemmy or outside of Lemmy.
-No Witch Hunts against users/communities.
-No content that harasses members within or outside of the community.
...
6. NSFW should be behind NSFW tags.
-Content that is NSFW should be behind NSFW tags.
-Content that might be distressing should be kept behind NSFW tags.
...
If you see content that is a breach of the rules, please flag and report the comment and a moderator will take action where they can.
Also check out:
Partnered Communities:
1.Memes
10.LinuxMemes (Linux themed memes)
Reach out to
All communities included on the sidebar are to be made in compliance with the instance rules. Striker
It goes like this, on the the 25th. A minor shock? No. Death madeshift.
The baffled men are meeting now their maker.
Hallelujah, Hallelujah,
Hallelujah, Hallelujah!
Also known as a "nope rope"
I thought that was a snake....
I wouldn't plug both ends of a snake into the mains either.
We call them a Deadman's cable up here, and sadly they're still quite frequently used in the northern rural areas because it costs almost $2,000 to have a dedicated bypass switch installed(generator hookup) so nobody does it, they just throw the Main and hope they don't put too much stress on the internal lines.
Is it legal? Hell no but they do it anyway
I did this.
Is it stupid? Yes.
Did it work? Also yes.
For the amount of time that we'd have power out, it was just way to easy to throw a breaker and connect it like this just to keep a small heater and a light running. If I had the money at the time I would have loved battery backup/ bypass but this cost $2 and an old cord.
I thought this was an anti homosexuality meme until I read the top comment.
I've got to stop using Lemmy. It is changing me...
I too have developed into a very politically correct person with lemmy, I kinda miss being able to make gay jokes
I heard there was a secret cord.
you plug it in to meet the lord.
But you don't really care for safety, do ya?
It goes like this, you plug it in,
And in a flash, the lights go dim,
The power's gone,
and now it’s running through ya.
They very much do exist, though. Often used sketchily with generators.
How do you non-sketchily feed a generator's power into your home?
You get a qualified tradesperson to wire it properly into your electrical distribution.
Technical details and the social contract mandate that your generator is never connected to the main power grid. The generator should be wired to an enclosed AC transfer switch. This switch will connect either the generator or the main grid to your home, but never both.
Some detail: If the generator is wired to the main grid it can prevent restoration of main grid power. While an AC transfer switch will perform the task, many jurisdictions mandate additional safety precautions (which can be quite expensive).
It can also kill a lineman working on the power lines outside your house, thinking they’re not energized.
The proper way of doing it is using what's called a generator bypass switch, basically it's a physical switch that runs before your fuse box, and it makes it impossible to have both the main and the generator being fed at the same time, so you can either have the main on or you could have the generator on. This prevents the electricity from your generator back feeding into the line and killing a line worker trying to restore power.
Sadly, like the other comments have said people tend to use these male to male cables in order to not have to pay the $2,000 to install the switch and instead choose to just turn the main breaker off and plug that cable in. But since it's possible to have both the main and the generator on it's not legal because if you forgot to throw the Main or if you did it incorrectly you could be putting workers at risk
Even disregarding the safety risk of using such a cable, not having a dedicated switch installed also means that you're plugging your generator into usually an outside socket of the house, and those power lines aren't usually meant to have a high load so you risk creating a fire from over straining the line as well
There are electrical panel accessories that automatically isolate the house
I'm not American, Christmas lights aren't a thing here like they're in the US, can someone explain?
Strand of exterior lights, one end male plug one female. Idiots start to mount the lights with the female end near their outlet. Get done, become confused, go to store for male to male cord to plug into female end.
The female end is for chaining multiple strands, not for supplying power (directly) from the power socket.
The power can go through the female end just fine, that’s not the problem. The problem is people plug this “suicide cable” into the wall first, thus creating a 120v taser of sorts. Like someone else in this thread said, the only problem from cables like that is people tend to try to backfeed energy into the system with a generator or solar panels. Boom.
Also, at the end of the chain there is a male terminal exposed with live current. Could cause a fire I guess.
A strand of christmas lights resembles an extension cord, but they tend to be made of smaller gauge wire and obviously have little sockets for tiny light bulbs spaced along them. They typically have 2-prong male plug on one end, often with a 2-prong female pass through on the back so you could plug more than one strand into the same receptacle, and they usually end in a female plug so they can be daisy chained.
Sometimes, when installing them on a house or something, the person installing them may not pay attention to which direction is which, and end up installing them so that the female-only end is near where they intended to plug them in. So instead of pulling them down, or running a long extension cord, they go to the hardware store looking for a male-to-male plug adapter.
Power plugs and sockets are gendered for a very good reason; the female receptacle keeps the energized contacts protected inside, and the male plug's contacts should only be energized when plugged in and their outer shells protect them. A male-to-male cable when one end is plugged in and the other is free now has exposed mains current just waving around in the open air ready to kill someone. And, on a smaller note with christmas lights, they usually have a fuse built into the plug, and plugging them in backwards bypasses this for at least the first strand, so it's technically 102.7% unsafe to do this.
The other thing a male-to-male adapter or cable is sometimes used for is to attach a portable generator to your home's electrical system by just plugging it into an outlet, especially during a power failure. They do make what are essentially special male receptacles I think mainly for the RV industry for attaching generators like that, most houses won't have these. Plugging it into a normal wall socket will actually work, but 1. you have bypassed the breaker panel, so the breakers no longer provide over-current protection. You could overheat the wires in the walls and burn down the house. 2. there's a possibility that you're feeding electricity to the entire house through the breaker box and even out to the transformer, which means the lines could be energized for linemen working on them. Throwing the main breaker might prevent that? They make switching gear designed for buildings with their own backup generators that can either manually or automatically sever their connection to the grid when on internal power, but again a doofus trying to make one of these cables probably doesn't have one of those.
Their lights usually have a plug on one end and a socket on the other. Ppl put them around the exterior of their hoses, then realise they did it the wrong way, and the socket end is near the outlet they wanted to plug them in.
Or they mounted two strands of lights, and where they meet up it’s either 2 plugs or two sockets accidentally.
as someone who has strung a ton of lights the wrong way around on more than one occasion... I can understand the desire for some magic solution that doesnt require undoing and redoing your work..
but fuck, You don't mess around with electricity.
People also make these stupid suicide cables to plug generators into houses during disasters, often backfeeding power into the lines that may be down and can cause serious injury to workers trying to restore power.
Just use 2 paper clips and some duct tape, problem solved!
I've used a suicide cord before in some rare instances. When I was finished I immediately took it apart.
https://www.youtube.com/watch?v=H-4mvK2FW78
Plugging the cord in the same outlet isn't dangerous itself, but the prongs will be live on the end that's not plugged in, I'd suggest not touching them. Where it IS dangerous is when people try to use them with a generator to back feed their panel. Don't do that.
On the one hand, there are legitimate uses for double ended male cords. On the other, absolutely none of those legit uses invovle christmas lights
It's also good to backfeed a generator into an outlet
I don't really get it. Sure, the exposed prongs would be energized once you plugged one side in, but if you plugged the other side into a second outlet (assuming you didn't cross live/neutral), nothing would happen. (those two outlets were likely tied together anyway)
You don't work around dangerous things assuming you'll never make a mistake, you work around dangerous things assuming you'll never make three mistakes at the same time.
You are not immune to making one (or more) mistakes, no matter how careful you think you are.
Well, maybe it's because you may die if you accidentally touched touched the prongs? The purpose of female plugs is among other reasons to prevent accidentally touching them.
In addition to the exposed prongs, it also means you are passing current into a circuit of unknown capacity without using a safety breaker. You may also be back feeding into your neighborhood power grid and can kill people in the street/other houses that were not expecting the lines to be energized.
The problem really is the super exposed hot prong you now have once you plug one end in
50-50 chance whether those two outlets are on the same phase or opposite phases; if it's the latter, congrats, that's a 240V short.
Besides, if there's an outlet at the far end of your string of lights, you don't need this, you just plug it in there